Product Information
CAST IN PLACE (CIP) TGSIs
> Cast In Place (CIP) TGSIs - Select
Product Type Selection
If you are familiar with Tactile Ground Surface Indicators (TGSIs) and know what you are looking for, please click on either the WARNING or DIRECTIONAL TGSI image below for direct navigation to the product information that you require.
Please Call: 1300 665 761 if you require any assistance.
> Cast In Place (CIP) TGSIs - Overview
Product Summary
WARNING & DIRECTIONAL TGSIs
What are ESP CIP TGSIs?
The ESP Warning and Directional Integrated Cast in Place (CIP) TGSI Access Tile is applied during the curing of wet concrete. When the concrete becomes cured, the ESP CIP TGSI Access Tile, is subsequently mechanically fixed to the finished substrate. Corrosion resistant, nylon composite hexagonal anchors and countersunk tamper proof 304 stainless steel fasteners, provide an additional mechanical connection between the ESP CIP TGSI Access Tile and the substrate.
Image: Cast in Place TGSI Access Tile installation on a Kerb Ramp.
Why do ESP Cast In Place TGSIs perform so well?
Each ESP TGSI Access Tile is manufactured through the method of high-pressure compression process of a Sheet Moulding Compound (SMC). Produced with our unique Herculite material, we construct every ESP Access Tile from the highest quality polymer components and, with additional UV stabilisers for the harsh Australian Sun, the ESP Access Tiles will maintain their individual Luminance Contrast Values over the long term.
Image: Product Material Testing for the ESP Cast In Place TGSI Access Tile in Accordance with the American Standard Testing Methods (ASTM) - ASTM C 501-84 - Test: Relative Resistance To Wear.
How TOUGH are ESP Cast In Place TGSIs?
So what happens when large, heavy trucks cut corners and repeatedly drive over the nature strip? What about when they drive over the pedestrian kerb ramps with TGSIs installed on them? Which comes off better? The ESP TGSIs or the concrete kerb ramp?
As you can see from the images below, where trucks have driven over the pedestrian crossing, the concrete around the ESP CIP TGSI Access Tiles has cracked. The ESP CIP TGSI Access Tiles have not. They are as good as the day that they were installed and remain fit-for-purpose.
With 24 international engineering tests and over 20 years of application experience throughout the world, ESP CIP TGSI Access Tiles are the most robust, durable and functional TGSIs for pedestrian streetscapes.
Image: There is no damage to the ESP Cast in Place TGSI Access Tiles. It is still fit for purpose. Howere, the concrete around the TGSI installation has cracked and is beyond repair. The entire Kerb Ramp needs to be completely replace recertified by the local council inspector.
> Warning (CIP) - Product Overview
Warning (CIP) TGSIs
Product Overview
ESP Product Codes
ESP-CIP-INT-WAR-TGSI-600x300
ESP-CIP-INT-WAR-TGSI-1200x600
Group
Tactile Ground Surface Indicators (TGSIs)
Type
WARNING
(Truncated Domes)
Configuration
Integrated Type - (TGSIs that are in a defined pattern and which are of the same luminance and material as the product's base surface)
Surface Application
Each ESP CIP Warning TGSI Access Tile is designed to be applied to the un-set or un-cured substrate or surface; predominately concrete. Additional installation methods are referenced in the ESP Technical Product Data (TPD) Documents for each ESP TGSI Access Tile product.
Product Material
Fibre-reinforced Herculite polymer
Physical Environments
Internal & External, Hot & Freezing, Wet & Dry
Intended Use
The intended use of this product must meet compliance with AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 - Section A 2.1 (a), (b),(c), (d), (e), (f) and, 2.2 (a), (b) (i) and installed as to the tested results, as independently verified, in accordance with Appendix E of the above standard.
Removable Film
During the manufacturing process, a removable plastic film is applied to each ESP Cast In Place TGSI to the trafficable top surface protect it from dirt and damage during the application process in wet concrete.
Example of Removable Film: (Product appearance may vary)
Dimensional Drawings
600 x 300
1200 x 600
Dimensional Drawing Notes
Detailed and specific technical, engineering and compliance product information about the ESP Cast In Place (CIP) TGSI Access Tile, is available from ESP Australia on request. Please quote the applicable product code for each Technical Product Data (TPD) document as required.
Note: All dimensions are in millimetres and are not to scale
Finished Surface/Substrate Application
Ceramic & Vitrified Tiles,
Timber & WPC Decking,
Concrete, Masonry,
Exposed Aggregate,
Concrete Pavers,
Brick Pavers,
Asphalt,
Bluestone, Granite,
Limestone,
Sandstone,
Engineered Stone,
Vinyl,
Carpet (Thick) - Loop Pile (with Underlay)
Installation Methods
Method 5 -
Cast In Place
(during the curing of wet concrete)
Method 6 -
Boxed, Cast In Place
(during the curing of wet concrete)Method 7 -
Drill, Clean, Plug, Pack, Glue & Fixing
Method 8 -
Set-Down, Drill, Clean, Plug, Pack, Glue & Fixing
Method 9 -
Recess, Board, Drill, Clean, Plug, Pack, Glue & Fixing
> Warning (CIP) - Product Range
Cast In Place (CIP) TGSIs
Product Range Overview
Product Range
Product Colour
White
ESP Product Codes
ESP-CIP-INT-WAR-TGSI-600x300-WHITE
ESP-CIP-INT-WAR-TGSI-1200x600-WHITE
Luminance Contrast Rating
Dry= 73.2
Wet= 72.5
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated WARNING TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 68
Result: P5
AS4586:2013 A - (Slider 55) -
Class: 55
Result: P5
AS4586:2013 C -
Class: 29º
Result: C
AS4586:2013 D - (Amdt 1:2017) -
Class: 24º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 2 - Criteria And Application Of Warning Tactile Ground Surface Indicators.
Type: The design and arrangement of Warning TGSIs Clause 2.3.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
Product Colour
Yellow
ESP Product Codes
ESP-CIP-INT-WAR-TGSI-60ox300-YELLOW
ESP-CIP-INT-WAR-TGSI-1200x600-YELLOW
Luminance Contrast Rating
Dry= 55.3
Wet= 54.2
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated WARNING TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 68
Result: P5
AS4586:2013 A - (Slider 55) -
Class: 55
Result: P5
AS4586:2013 C -
Class: 29º
Result: C
AS4586:2013 D - (Amdt 1:2017) -
Class: 24º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 2 - Criteria And Application Of Warning Tactile Ground Surface Indicators.
Type: The design and arrangement of Warning TGSIs Clause 2.3.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
Product Colour
Black
ESP Product Codes
ESP-CIP-INT-WAR-TGSI-600x300-BLACK
ESP-CIP-INT-WAR-TGSI-1200x600-BLACK
Luminance Contrast Rating
Dry= 3.1
Wet= 2.5
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated WARNING TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 68
Result: P5
AS4586:2013 A - (Slider 55) -
Class: 55
Result: P5
AS4586:2013 C -
Class: 29º
Result: C
AS4586:2013 D - (Amdt 1:2017) -
Class: 24º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 2 - Criteria And Application Of Warning Tactile Ground Surface Indicators.
Type: The design and arrangement of Warning TGSIs Clause 2.3.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
> Directional (CIP) - Product Overview
Directional (CIP) TGSIs
Product Overview
ESP Product Codes
ESP-CIP-INT-DIR-TGSI-600x300
Group
Tactile Ground Surface Indicators (TGSIs)
Type
DIRECTIONAL
(Truncated Bars)
Configuration
Integrated Type - (TGSIs that are in a defined pattern and which are of the same luminance and material as the product's base surface)
Surface Application
Each ESP CIP Directional TGSI Access Tile is designed to be applied to the un-set or un-cured substrate or surface; predominately concrete. Additional installation methods are referenced in the ESP Technical Product Data (TPD) Documents for each ESP TGSI Access Tile product.
Product Material
Fibre-reinforced Herculite polymer
Physical Environments
Internal & External, Hot & Freezing, Wet & Dry
Intended Use
For each ESP Directional Tile to be effective, the intended use of this product must meet compliance with AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 - Section 3 - 2.1 (a), (b), (c), 2.2 (a), (b) and 2.3 installed as to the tested results, as independently verified, in accordance with Appendix E of the above standard.
Removable Film
During the manufacturing process, a removable plastic film is applied to each ESP Cast In Place TGSI to the trafficable top surface protect it from dirt and damage during the application process in wet concrete.
Example of Removable Film: (Product appearance may vary)
Dimensional Drawings
600 x 300
Dimensional Drawing Notes
Detailed and specific technical, engineering and compliance product information about the ESP Cast In Place (CIP) TGSI Access Tile, is available from ESP Australia on request. Please quote the applicable product code for each Technical Product Data (TPD) document as required.
Note: All dimensions are in millimetres and are not to scale
Finished Surface/Substrate Application
Ceramic & Vitrified Tiles,
Timber & WPC Decking,
Concrete, Masonry,
Exposed Aggregate,
Concrete Pavers,
Brick Pavers,
Asphalt,
Bluestone, Granite,
Limestone,
Sandstone,
Engineered Stone,
Vinyl,
Carpet (Thick) - Loop Pile (with Underlay)
Installation Methods
Method 5 -
Cast In Place
(during the curing of wet concrete)
Method 6 -
Boxed, Cast In Place
(during the curing of wet concrete)Method 7 -
Drill, Clean, Plug, Pack, Glue & Fixing
Method 8 -
Set-Down, Drill, Clean, Plug, Pack, Glue & Fixing
Method 9 -
Recess, Board, Drill, Clean, Plug, Pack, Glue & Fixing
> Directional (CIP) - Product Range
Directional (CIP) TGSIs
Product Range
Product Colour
White
ESP Product Codes
ESP-CIP-INT-DIR-TGSI-60ox300-WHITE
Luminance Contrast Rating
Dry= 74.6
Wet=73.7
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated DIRECTIONAL TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 54
Result: P4
AS4586:2013 A - (Slider 55) -
Class: 41
Result: P4
AS4586:2013 C -
Class: 16º
Result: A
AS4586:2013 D - (Amdt 1:2017) -
Class:22º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 3 - Criteria And Application Of Directional Tactile Ground Surface Indicators.
Type: The design and arrangement of Directional TGSIs Clause 3.2.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
Product Colour
Yellow
ESP Product Codes
ESP-CIP-INT-DIR-TGSI-60ox300-YELLOW
Luminance Contrast Rating
Dry= 57.2
Wet= 54.3
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated DIRECTIONAL TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 54
Result: P4
AS4586:2013 A - (Slider 55) -
Class: 41
Result: P4
AS4586:2013 C -
Class: 16º
Result: A
AS4586:2013 D - (Amdt 1:2017) -
Class:22º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 3 - Criteria And Application Of Directional Tactile Ground Surface Indicators.
Type: The design and arrangement of DIrectional TGSIs Clause 3.2.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
Product Colour
Black
ESP Product Codes
ESP-CIP-INT-DIR-TGSI-600x300-BLACK
Luminance Contrast Rating
Dry= 5.2
Wet= 3.5
Important Note about luminance contrast: For Information about luminance contrast or to determine a luminance contrast between a finished substrate and the ESP Cast In Place Integrated DIRECTIONAL TGSI Access Tiles see: AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1, should be used as of 26.11.2010.
Slip Resistance Classifications
AS4586:2013 A - (Slider 96) -
Class: 54
Result: P4
AS4586:2013 A - (Slider 55) -
Class: 41
Result: P4
AS4586:2013 C -
Class: 16º
Result: A
AS4586:2013 D - (Amdt 1:2017) -
Class:22º
Result: R11
Important information about slip resistance ratings: For information about slip resistance ratings or to determine a classification of a slip resistance rating, see Standards Australia HandBook - SA HB 198:2014: Guide to the Specification and Testing of Slip Resistance of Pedestrian Surfaces. This document outlines the minimum ratings of a location and situation of a pedestrian surface.
Dimensional Compliance
AS/NZS 1428.4.1:2009 Section 3 - Criteria And Application Of Directional Tactile Ground Surface Indicators.
Type: The design and arrangement of Directional TGSIs Clause 3.2.2 Comply with design requirements =
Result: YES - Complies
Technical Product Data
Comprehensive Product Specification and Application Information is contained in the following Document.
> Installation Notes
Warning and Directional (CIP) TGSIs
Installation Notes
Product and Quality Standard
Mechanically and Chemically Secured
Each ESP Warning and Directional Tile is Cast in Place during the curing of Wet Concrete.
When the Concrete becomes cured, The ESP Directional Tile will then be mechanically fixed to the finished surface or substrate. Corrosion Resistant, Nylon Composite Hexagonal Anchors and, 304 Counter Sunk Tamper Proof Stainless Steel Fasteners, provide additional mechanical connection between the ESP Directional Tile and the substrate.
No Lifting Edges
The Cast in Place ESP Warning and Directional Tile also eradicates any likelihood of its perimeter lifting over its lifespan. This unique product feature is designed to meet compliance with AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 - Clause 3.2.1 (a) & (e).
Alternative Application Fixing Methods and Surface Applications
Each ESP CIP Access Tile can also be installed into or onto surfaces that do not require the unique ESP Cast In Place (CIP) process during the curing of Wet Concrete.
Where the ESP CIP Access Tiles can be recessed into the finished Surface or Substrate alternative and durable methods can be facilitated.
Applicator and Person intending to install ESP CIP Warning and Directional TGSIs
It is essential that anyone installing, applying, or maintaining the following ESP Directional Tile products, are trained and inducted in their application and use:
Training (Minimum) & Induction
Installer and applicators must be trained and inducted by ESP Australia P/L in the relevant application method of ESP Warning and Directional TGSI products. Failure to do so will void the product warranty offered by ESP Australia.
Occupational Workplace Safety (OWS)
Any responsible entity must be familiar with and have in place, the relevant work practices and insurances as to provide a safe work environment for the inducted installers and applicators who are to apply ESP Warning and Directional TGSI products.
Personal Protective Equipment (PPE)
Always use personal protective equipment (PPE) when applying the ESP Australia Warning and Directional TGSI products.
The following items should be worn when applying the ESP Warning and Directional TGSI products:
(a) eye protection,
(b) hand protection,
(c) safety boots and,
(d) protective clothing for the hands, upper and lower body.
Please note: If you are using electric cutting, drilling, grinding or other application tools then ear protection and additional safety clothing are recommended.
Installation Services can be facilitated through ESP Australia on request.
To check the Accredited ESP Applicator Network, call now on 1300 665 761
Mandatory Compliance with Applicable Legislation, Standards and Codes
Intended Use of ESP CIP WARNING TGSIs
The ESP Warning and Directional TGSIs are designed to enhance the safety, dignity and independence of people who are blind or vision impaired so that they have barrier free access to the built environment. Each ESP Warning and Directional TGSI provides cues which when combined with other environmental information assist people who are blind or vision-impaired.
WARNING TGSIs
For each ESP Warning Tile to be effective, the intended use of this product must meet compliance with AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 - Section A 2.1 (a), (b), (c), (d), (e), (f) and, 2.2 (a), (b) (i) and installed as to the tested results, as independently verified, in accordance with Appendix E of the above standard.
DIRECTIONAL TGSIs
For each ESP Directional Tile to be effective, the intended use of this product must meet compliance with AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 - Section 3 - 2.1 (a), (b), (c), 2.2 (a), (b) and 2.3 installed as to the tested results, as independently verified, in accordance with Appendix E of the above standard.
A copy of AS/NZS 1428.4.1:2009 Amdt No.s 1 & 2 can be purchased from SAI GLOBAL
Application - Fit-for-purpose
Prior to any application of the ESP Warning and Directional TGSIs, all sites should be inspected.
This will ensure that the products will be fit for the intended purpose and the proposed finished surface. The will also provide the opportunity for the applicator to confirm the integrity of the finished surface that the ESP Warning and Directional TGSIs will be installed onto.
Positioning of Tactile Ground Surface Indicators (TGSIs)
ESP Australia recommends that the proposed design layout for the ESP Warning and Directional TGSI installation, should also be assessed, prior to installation, to ascertain if the application will achieve compliance with the applicable codes and standards.
ESP Australia recommends that any assessment should only be done by a qualified and knowledgeable person who is experienced and fluent in the use of TGSIs within Australia and New Zealand.
Site Compliance with Luminance Contrast
Every finished surface and/or substrate is different and so presents its own nuances of luminance. ESP Australia strongly recommends that luminance contrast testing of the substrate, (finished surface - that being the finished surrounding surface in line with the accessible path of travel), be tested for its luminous value so as to determine that the chosen ESP TGSI has sufficient luminance contrast as required by AS/NZS 1428.4.1. Amendment 1 - 2010-11-26 Appendix E and specifically Table E1 should be used.
This will determine if the colour of the selected ESP Warning and/or Directional TGSI will be compliant with the applicable legislation, standards and codes.
> Installation Methods
Warning and Directional (CIP) TGSIa
Installation Methods for Finished Surfaces
Method No.5
Concrete, Masonry, Exposed Aggregate, Terrazzo
Installation Method
Installation Type No.17
Cast In Place -
(during the curing of wet concrete)
Tools & Equipment Required
Set down TGSI frame, rubber mallet, tape measure. Fixings are supplied.
Installation Diagram No.17
Method No.6
Concrete Pavers
Installation Method
Installation Type No.18
Boxed
Cast In Place -
(during the curing of wet concrete)
Tools & equipment Required
Set down TGSI frame, rubber mallet, tape measure & concrete boxing. Fixings are supplied.
Installation Diagram No.18
Brick Pavers
Installation Method
Installation Type No.19
Boxed
Cast In Place -
(during the curing of wet concrete)
Tools & equipment Required
Set down TGSI frame, rubber mallet, tape measure & concrete boxing. Fixings are supplied.
Installation Diagram No.19
Asphalt
Installation Method
Installation Type No.20
Boxed
Cast In Place -
(during the curing of wet concrete)
Tools & equipment Required
Set down TGSI frame, rubber mallet, tape measure & concrete boxing. Fixings are supplied.
Installation Diagram No.20
Method No.7
Ceramics, Vitrified Tiles
Installation Method
Installation Type No.21
Drill
Clean
Plug
Pack
Glue & Fixing
Tools & equipment Required
Set down TGSI frame, Plywood, tape measure & concrete boxing. Cordless drill, drill bits, Isopropyl alcohol, clean rags, hammer & rubber mallet. Fixings & plugs are supplied.
Installation Diagram No.21
Bluestone, Granite, Limestone, Sandstone, Engineered Stone
Installation Method
Installation Type No.22
Drill
Clean
Plug
Pack
Glue & Fixing
Tools & equipment Required
Set down TGSI frame, Plywood, tape measure & concrete boxing. Cordless drill, drill bits, Isopropyl alcohol, clean rags, hammer & rubber mallet. Fixings & plugs are supplied.
Installation Diagram No.22
Carpet (Thick) - Loop Pile (With Underlay)
Installation Method
Installation Type No.23
Drill
Clean
Plug
Pack
Glue & Fixing
Tools & equipment Required
Set down TGSI frame, Plywood, tape measure & concrete boxing. Cordless drill, drill bits, Isopropyl alcohol, clean rags, hammer & rubber mallet. Fixings & plugs are supplied.
Installation Diagram No.23
Method No. 8
Vinyl
Installation Method
Installation Type No.24
Set-Down
Drill
Clean
Plug
Pack
Glue & Fixing
Tools & equipment Required
Concrete recess, set down TGSI frame, plywood, tape measure. Cordless drill, drill bits, Isopropyl alcohol, clean rags, hammer & rubber mallet. Fixings & plugs are supplied.
Installation Diagram No.24
Method No. 9
Timber, Wood Plastic Composite (WPC) and Decking timber
Installation Method
Installation Type No.25
Recess
Board
Drill
Clean
Plug
Pack
Glue & Fixing
Tools & equipment Required
Compressed cement sheet on joists and packing, tape measure, cordless drill, drill bits, Isopropyl alcohol, clean rags, Fixings & plugs are supplied.
Installation Diagram No.25
> Installation Services
Installation Services
Services Offered by ESP
Installation
Installation Services can be facilitated through ESP Australia on request.
To check the Accredited ESP Applicator Network, call now on 1300 665 761
To inquire about a specialised service from ESP, call 1300 665 761 or send and email through our contact page. Click Here
Consultation and Advice
Through it’s professional network, ESP Australia can also arrange and provide on site testing services including:
Project TGSI Luminance Testing
Project TGSI Slip Resistance Testing
TGSI Application and Installation Advice
Special TGSI Products for Municipalities
TGSI Estimating and Project Quantity Surveying
Coordination of TGSI Installation
TGSI Product Induction & Training
> Installation Maintenance
Warning and Directional (CIP) TGSIs
ESP Product Maintenance and Replacement
Cast In Place during the curing of wet concrete, ESP CIP TGSIs are also replaceable.
With continual rise of meeting compliance with the built environment we’ve thought long and hard about how we can save you money over the long term.
The ESP Cast In Place TGSI Access Tile can be maintained in a very fast and cost-effective manner and at no additional expense; it’s simply built into very ESP CIP TGSI product.
Replacement
Each ESP Warning and Directional CIP TGSI is designed with the optimal use of material and is conveniently replaceable with the specific ESP application tools. If replacement is required, for whatever reason, it is recommended that an assessment is conducted by one of ESP Australia's product engineers.
The typical re-installation sequence for ESP Cast in Place involves a step process as described below:
Step 1 - Remove Existing TGSIs
Step 2 - Replace ESP CIP TGSI Tile
Step 3 - Affix with tamper proof fixings
Please Call: 1300 665 761 if you require any assistance with service or replacement of ESP TGSIs.
Image: Cross section view of ESP Cast In Place TGSI installed into concrete substrate.
Contact ESP for personalised service with your project